990 resultados para Intra-aortic Balloon Pumping


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Management of acute heart failure is an important consideration in critical care. Mechanical support of the failing heart is crucial for improving health outcomes. The most common Australasian application of intraaortic balloon counterpulsation (IABP) is in the setting of cardiogenic shock. High end users of IABP (>37/annum) demonstrate significantly lower mortality for cardiogenic shock managed with IABP (p <0.001) in contrast to hospitals which employ limited IABP (<4/annum). This underscores the importance of proficiency in managing patient receiving IABP support. Nurses play a crucial role in carding for patients with acute heart failure. This paper summarises care considerations for management of the IABP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intra-aortic balloon pumping is a counter pulsation technique for temporary circulatory assistance in cardiogenic shock and other low cardiac output conditions. Conventional systems use a balloon at the end of a catheter driven by a solenoid valve, controlled by patient's ECG or ventricular pressure signal. This results in time delay introducted by solenoid spool inertia, gas inertia, and hysteresis effects of the solenoid. Fluidics, because of their non-moving part operation and high switching speeds, minimizes the inertial effects while contributing high reliability. This communication describes a fluidic system developed for driving the balloon accepting electric control signals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and inflation ratio weaning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intraaortic balloon pumping (IABP) is an established treatment for the support of a failing heart (Christenson, Simonet et al. 1997). It is a process undertaken in most level two and three intensive care units. Despite IABP appearing complex, the principles are straightforward. A sausage shaped intraaortic balloon (IAB) about 250 millimetres long and 15 millimetres in diameter, is placed in the descending aorta and attached to an external pump. The external pump then inflates and deflates the IAB in synchrony with cardiac contraction. The primary purpose of this is the support of a compromised heart with a simultaneous increase in myocardial oxygen supply, and decrease in myocardial oxygen demand (Overwalder, 1999). As a nurse it is worthwhile understanding the principles of IABP. As a hospital intervention, it’s exposure to nursing is high.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two control algorithms have been developed for a minimally invasive axial-flow ventricular assist device (VAD) for placement in the descending aorta. The purpose of the device is to offload the left ventricle and to augment lower body perfusion in patients with moderate congestive heart failure. The VAD consists of an intra-aortic impeller with a built-in permanent magnet rotor and an extra-aortic stator. The control algorithms, which use pressure readings upstream and downstream of the VAD to determine the pump status, have been tested in a mock circulatory system under two conditions, namely with or without afterload sensitivity. The results give an insight into controller design for an intra-aortic blood pump working in series with the heart.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A permanent-magnet motor has been designed for an innovative axial-flow ventricular assist device (VAD), to be placed in the descending aorta, intended to offload the left ventricle and augment renal perfusion in patients with congestive heart failure (CHF). For this application, an intra-aortic impeller with a built-in permanent magnet rotor is driven by an extraaortic stator working in synchronism with the natural heart. To meet this need, a two-dimensional analytical model has been developed in the MATLAB environment to estimate machine parameters; finite element analysis (FEA) has been used to refine the results. A prototype blood pump equipped with an innovative motor designed from the procedure above has been tested in a mock loop representing the human circulatory system. The performance of VAD incorporating the motor is presented. © 2009 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN]In this project has been developed a tool which synthesizes realistic waveforms produced by the intra-aortic balloon pump. In addition the following waveforms have also been synthesized: arterial blood pressure (ABP) waveform, the four variations produced due to timing errors of the balloon and the waveform of the helium gas rapidly shuttling in and out of the balloon chamber. All waveforms are synthesized in synchrony with the balloon's inflation/deflation cycles. A database composed of annotated ECG (Electrocardiogram) normal sinus rhythm records has also been created during the project. In order to facilitate the work, two graphical user interfaces were developed. The first interface allows the selection of the ECG records, which were latter annotated using the second interface. Starting from the newly created annotated database, the different waveforms, mentioned above, were synthesized. In this document, in view of the synthesized waveforms, it can be concluded that the obtained results are satisfactory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION : L’utilisation de la circulation extracorporelle durant la chirurgie cardiaque est associée à des problèmes pulmonaires chez certains patients. L’utilisation d’une pression pulsatile induite par un ballon intra-aortique (BIA) pourrait diminuer la dysfonction endothéliale et la survenue de tels événements. MATÉRIEL ET MÉTHODE : 12 porcs Landrace-Yorkshire ont subi une circulation extracorporelle et ont été divisés en deux groupes et 4 porcs ont servi de contrôles sans CEC. Le premier groupe (n=6) a bénéficié d’un flot pulsatile créé par un BIA en mode interne à 80 battements par minute durant les 90 minutes de l’opération alors que le second groupe (n=6) a subi une CEC standard. Après 60 minutes de reperfusion suivant la CEC, les valeurs hémodynamiques ont été évaluées dont les pressions artérielles, les pressions pulmonaires, l’index cardiaque et la concentration de glucose et de lactate. Les artères pulmonaires sont ensuite montées en chambre d’organe pour évaluer la fonction endothéliale. RÉSULTATS : Les porcs avec pression pulsatile ont tendance à produire moins de lactate sanguin après 60 minutes de reperfusion. Les autres valeurs hémodynamiques sont semblables. Finalement, la relaxation à la bradykinine est significativement meilleure dans le groupe pression pulsatile alors que la relaxation à l’acétylcholine n’est pas significativement différente. CONCLUSION : Ces résultats démontrent que la perfusion pulsatile produite par un BIA protège l’endothélium pulmonaire lors d'une CEC. Cet effet pourrait être dû à une augmentation du flot bronchique qui diminuerait l’ischémie pulmonaire ou à une diminution de la libération de cytokines et de bradykinine qui réduirait les dommages de reperfusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: A esternotomia mediana longitudinal é a via de acesso mais utilizada no tratamento das doenças cardíacas. As infecções profundas da ferida operatória no pós-operatório das cirurgias cardiovasculares são uma complicação séria, com alto custo durante o tratamento. Diferentes estudos têm encontrado fatores de risco para o desenvolvimento de mediastinite e as variáveis pré-operatórias têm tido especial destaque. OBJETIVO: O objetivo deste estudo é identificar fatores de risco pré-operatórios para o desenvolvimento de mediastinite em pacientes submetidos a revascularização do miocárdio e a substituição valvar. MÉTODOS: Este estudo observacional representa uma coorte de 2768 pacientes operados consecutivamente. O período considerado para análise foi de maio de 2007 a maio de 2009 e não houve critérios de exclusão. Foi realizada análise univariada e multivariada pelo modelo de regressão logística das 38 variáveis pré-operatórias eleitas. RESULTADOS: Nesta série, 35 (1,3%) pacientes evoluíram com mediastinite e 19 (0,7%) com osteomielite associada. A idade média dos pacientes foi de 59,9 ± 13,5 anos e o EuroSCORE de 4,5 ± 3,6. A mortalidade hospitalar foi de 42,8%. Na análise multivariada, foram identificadas três variáveis como preditoras independentes de mediastinite: balão intra-aórtico (OR 5,41, 95% IC [1,83 -16,01], P=0,002), hemodiálise (OR 4,87, 95% IC [1,41 - 16,86], P=0,012) e intervenção vascular extracardíaca (OR 4,39, 95% IC [1,64 - 11,76], P=0,003). CONCLUSÃO: O presente estudo demonstrou que necessidade do suporte hemodinâmico pré-operatório com balão intra-aórtico, hemodiálise e intervenção vascular extracardíaca são fatores de risco para o desenvolvimento de mediastinite após cirurgia cardíaca.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Complete arterial CABG is a surgical option to improve long-term results in the treatment of coronary artery disease (CAD). Harvesting of multiple arterial grafts is commonly associated with prolonged operating times and increased trauma. By use of new operative techniques (skeletonized grafts and the T-graft approach), CABG in multivessel CAD is now possible with only 2 grafts. We present our experience in the use of these techniques on a routine basis. METHODS AND RESULTS: Between March 1996 and September 1999, 490 patients (aged 61+/-9 years, 20% female) underwent complete arterial CABG. Left ventricular ejection fraction ranged from 15% to 85% (mean 59+/-15%). Triple-vessel disease was present in 88% of the patients. The incidence of diabetes mellitus was 32% (14% insulin dependent). Either both internal thoracic arteries (ITAs) (23%) or the left ITA and radial artery (77%) were used as conduits. In 85% of the patients, a T graft was created. Mean operating time was 198+/-46 minutes; bypass time, 82+/-25 minutes; and ischemic time, 58+/-22 minutes. Two to 7 (mean 4.1+/-0.9) anastomoses were performed per patient. Perioperative intra-aortic balloon pump was necessary in 12 patients (2.4%). The rate of perioperative myocardial infarction was 1.2%. Sternal complications occurred in 1. 0%, and in-hospital mortality was 2.2%. Postoperative coronary angiography in 172 patients (35%) documented excellent patency rates (left ITA 98.3%, right ITA 96.5%, and radial artery 96.6%). CONCLUSIONS: Complete arterial revascularization in multivessel CAD is possible with the use of only 2 grafts with good perioperative results. This approach allows for complete arterial CABG on a routine basis.